What auxiliary heat means on an Oregon heat pump

Step 1 of 3: Equipment

What does auxiliary heat mean on my heat pump?

You turned on the heat and noticed the thermostat says "aux heat" or "emergency heat," and the system sounds different, maybe running longer or costing more to run. You're not sure if something's wrong with your heat pump or if this is just how it works. Since most homes in Oregon heat with electricity, you want to know what you're looking at before you decide whether to call anyone.

Auxiliary heat is backup electric heat that kicks in when your heat pump alone can't keep up

A heat pump pulls warmth from the outside air. As the outside temperature drops, there's less warmth out there to pull, so the heat pump works harder and puts out less heat. Auxiliary heat is a second heating element built into the system, usually electric resistance coils, that switches on to make up the difference on the coldest days or when the thermostat is set to jump up several degrees at once. Seeing "aux heat" on your thermostat during a cold snap is normal. It costs more to run than the heat pump alone, since electric resistance heat takes more power to produce the same warmth. If it's running when it's not especially cold out, or staying on for hours at a stretch, that points to the heat pump itself not keeping up, which is worth having looked at.

An outdoor condenser unit beside a horizontally sided house, encased in thick ice with hanging icicles, on a snow-dusted ground at sunset with bare trees in the background.

You walk out to the side yard before sunrise to grab something from the garage, and the outdoor unit stops you. It's coated in ice, thick over the coils, not just a frost skim. The sky is still dark, the kind of January morning where the cold settles in overnight. Inside, the thermostat has been reading "aux heat" since you got up, and the air coming through the vents feels warmer than usual, almost hot. You stand there a minute looking at the ice, wondering if it's supposed to look like that or if the unit's stuck trying to defrost itself and losing.

A gray outdoor condenser unit on a concrete pad beside a house with horizontal lap siding, with a wall-mounted disconnect box, conduit and insulated refrigerant lines, a shrub at left and gravel at right.
The coils are clean and the unit runs quiet, cycling on and off like it should on a cold Oregon morning.
An outdoor air conditioning condenser unit on a concrete pad beside a house with horizontal lap siding, with a green shrub to the left and a wide concrete slab in the foreground.
A heavy coat of ice over the coils like this means the unit can't pull heat from the air, and aux heat is covering the gap.

How Aux Heat Actually Works

  • A heat pump moves heat from the outside air into your house instead of burning fuel to make it.
  • Below the mid 30s, the outdoor coil can't pull enough heat from the air to keep up, so the system calls for aux heat.
  • Aux heat is a backup electric element, usually strip heat in the indoor air handler, not a separate furnace.
  • The outdoor unit runs a defrost cycle every so often, and aux heat often kicks in during that cycle to keep warm air moving.
  • Emergency heat is different: you set that yourself when the outdoor unit has stopped working and the house is running on the backup element alone.
  • Strip heat uses far more electricity than the compressor, which is why a long aux heat run shows up on the power bill.

A heat pump works by moving heat, not making it. The outdoor unit pulls warmth out of the air, even cold air, and the indoor unit spreads it through your ducts. That works fine most of the year. Once the outside temperature drops into the mid 30s and below, there's less heat in the air to grab, and the compressor alone can't keep the house at the temperature you set. That's when the system calls for aux heat, which is an electric heating element built into the air handler. People hear "auxiliary" and picture a second furnace tucked away somewhere, but it's strip heat, coils that glow and warm the air directly, wired right into the same indoor unit. You'll also see aux heat come on during defrost. The outdoor coil ices up in cold, damp weather, and the system periodically reverses itself to melt that ice off. While it's doing that, it isn't heating, so aux heat steps in to keep warm air coming through your vents. Emergency heat is a different setting, one you choose, not one the system picks on its own. If the outdoor unit has failed and the thermostat is set to emergency heat, the house is running entirely on that electric element until someone gets the compressor working again. Strip heat pulls a lot more power than the compressor does, so a thermostat stuck on aux for hours, especially outside of a defrost cycle, is worth paying attention to.

A man with grey hair and stubble in a dark sweater sits on a grey sofa indoors, looking off to the side, with a potted plant and a sunlit window behind him.
A man with gray hair, a beard and glasses, wearing a dark green sweater, sits on a gray sofa in a sunlit living room with a potted plant, table lamp and wooden sideboard behind him.
A middle-aged man with graying hair and a short beard sits on a blue sofa in a living room, looking toward a window, with a bookshelf, lamp and framed picture in the background.
A man with graying curly hair and a dark green sweater sits on a gray sofa in a sunlit living room, looking off to the side, with a framed picture, shelving, an armchair and a window with sheer curtains behind him.

Hand off the heat pump problem

A heat pump that leans on aux heat too often costs more to run every month it does it, and a system stuck in aux heat around the clock usually points to something failing to pull its share, a stuck reversing valve, a low refrigerant charge, a defrost control that isn't cycling right. Those aren't things to leave alone through an Oregon winter. Someone who services heat pumps in this area through the cold months knows which of those tends to fail first and what a normal defrost cycle looks like versus one that's stopped working. Sending the request means one local contractor, licensed for this work, gets it instead of your having to track someone down yourself. You can get back to the rest of your morning and let the system get looked at properly, rather than guessing at the thermostat while the aux light stays on.

What aux heat actually runs on

The electric element inside the air handler works like a toaster coil, heating the air directly as it passes through rather than pulling warmth from outside. It doesn't need the outdoor unit to do anything. That's why it still delivers heat during a defrost cycle or when the outdoor coil is iced over and useless. It's a straightforward resistance heater, the same principle as a space heater, just built into the ductwork. There's no compressor involved and no refrigerant cycle to lean on. It draws power straight from the breaker box, which is part of why running on aux heat for long stretches shows up on the electric bill.

Why your thermostat shows it at all

Most heat pump thermostats in Oregon homes are built to display aux heat separately from normal heat so you can see when the backup element kicks in instead of the compressor doing the work. That split matters because the two modes don't cost the same to run. If the display shows aux heat only during very cold mornings or short defrost cycles, that's the system doing what it's supposed to. If it shows aux heat most of the time the furnace runs, something upstream, usually on the outdoor unit, isn't pulling its weight and the backup element is covering for it.

Power costs 15.46 cents per kilowatt-hour statewide

At 15.46 cents a kilowatt-hour, every hour your system leans on aux heat instead of the heat pump shows up on the bill. The electric element draws a lot more power than the compressor does for the same warmth, so a system stuck in aux heat for days adds up fast.

EIA-861 2025 statewide residential average

A heat pump that only kicks into aux heat on the coldest mornings, then drops back to normal once the temperature climbs, is doing what it's supposed to do.

A heat pump stuck on aux heat through a mild afternoon, or one that never seems to switch back, has a contractor's attention written all over it.

An outdoor air conditioner condenser unit on a concrete pad beside a house with beige vinyl siding, with a gray electrical disconnect box and insulated refrigerant lines on the wall and river rock to the right.
Before you get your heat pump repair
A gray outdoor condenser unit sits on a concrete pad against a house wall with horizontal siding above a stone veneer base, with an electrical disconnect box and conduit on the wall and a leafy shrub in mulch to the left.
After you get your heat pump repair

Aux heat on only when it's cold out

The system switches to the electric element on the coldest mornings and back to the heat pump once the air warms up. That's the system working the way it should.

Send my request

Aux heat on no matter the temperature

The element is running even on a mild afternoon, or it never switches back to the heat pump at all. That points to a part that needs a licensed technician to find.

Send my request

Why has your power bill jumped since the cold hit?

You check the bill and it's higher than last month, higher than it should be for a few cold weeks. Most homes here heat with electricity, so a heat pump leaning on aux heat shows up fast. You might notice the air coming out of the vents feels hotter than usual, almost like a space heater, or the system runs long stretches without shutting off. If aux heat is only stepping in on the coldest mornings, that's normal. If it's running most of the day, every day, the house is costing more to heat than it should, and something is likely keeping the heat pump itself from doing its job.

Single-story house with gray horizontal lap siding, dark shingled gable roof, a small covered front porch with a dark door, and windows, set behind a patchy green and brown lawn under a clear blue sky.

Summer here isn't the problem. Oregon's summer air averages a dew point of 52°F, which is low, so your heat pump barely works to pull moisture out of the air when it's cooling the house. It can focus on dropping the temperature and not much else. That's a different machine than the one you're running right now. The same system that coasts through July is the one asking for aux heat on a cold January morning, because out here the hard season for a heat pump isn't summer. It's winter, when the outdoor air has little heat left to give.

NASA POWER T2MDEW county cells weighted by homes

Aux heat is the electric element stepping in when the heat pump can't pull enough warmth from the cold air on its own. Seeing it come on during a cold snap means the system is doing its job. Seeing it stay on through a mild afternoon, or running nonstop for days, means something else is wrong, a stuck reversing valve, a low charge, a defrost control that won't reset, and the heat pump isn't carrying its share of the work anymore. That's not something to watch and wait on, since every hour on aux heat instead of the heat pump costs more to run. A licensed contractor working on heat pumps in your area every winter can tell quickly which part has failed and get the system back to pulling heat the way it's supposed to, instead of leaving the electric element to do all the work.

A woman with shoulder-length brown hair wearing a beige knit cardigan sits in a gray upholstered armchair near a window, looking off to the side with a slight smile, with bookshelves blurred in the background.
A woman and a sleeping child wrapped together in a cream knitted blanket on a couch, with a potted plant, framed photo and lit lamp in the background.

One request and it's handed off

A heat pump stuck on aux heat is costing you more every day it runs that way, and most of the time it means a part failed rather than the cold air being too much for it. A local contractor who works on heat pumps all winter can look at the reversing valve, the charge, and the defrost control and tell you which one quit. Send the request and the search is off your plate. One licensed contractor in your area picks it up, not a handful of companies competing for your call.

Hand off my repair

Only one pro gets your request, so you hear from one company.

You only hire the pro if you want to.